Gas Turbine Hot Gas Path Parts Condition Assessment

United Kingdom · Siemens SGT5-4000F gas turbine

Client objective

First-stage turbine blades and ring segments were found damaged due to contact. Blade tips were not visible on borescope. The operator required clarity on remaining life, operational risk, and inspection requirements.

Our contribution

  • Assessed inspection data and unit operating data, and compared it with fleet data.
  • Estimated local temperatures, oxidation rates, and clearance-driven degradation mechanisms.
  • Provided clear guidance on inspection intervals, operational constraints, and strategic spare part procurement to protect availability.