Net Dependable Capacity Test

Kingdom of Saudi Arabia · Combined cycle power plant, GE 7FA gas turbines

Client objective

To obtain an independent, standard-compliant verification of Net Dependable Capacity and heat rate following a major outage, supporting contractual, regulatory, and commercial assurance.

Our contribution

  • Delivered a full, plant-wide Net Dependable Capacity Test in accordance with ASME PTC 46.
  • Developed correction curves and test procedures, and coordinated the test on site.
  • Processed the test data and delivered a report compliant with off-taker requirements.
Generated power vs compressor inlet temperature — plant operating data.
Generated power vs compressor inlet temperature — plant operating data.
Normalised plant power vs ambient temperature, with corrected test points overlaid.
Normalised plant power vs ambient temperature, with corrected test points overlaid.